Glass Blocks Direct Home Page
BUY BLOCKS WITH FIXINGS
FRAMELIGHT DRY FIX SYSTEM
FRAMELIGHT PV KIT
RODS & MORTAR KIT
BUY STANDALONE BLOCKS
MENDINI COLLECTION
CLEAR BLOCKS
SANDBLASTED BLOCKS
COLOURED BLOCKS
INTENSE COLOURS
PATTERNED BLOCKS
ITALIAN PEGASUS SATIN BLOCKS
ITALIAN PEGASUS BLOCKS
METALLISED PEGASUS BLOCKS
 CLEARANCE SECTION
BUY ACCESSORIES
FRAMELIGHT
FRAMELIGHT PV
CORNER & END POSTS
FINISHING TILES
EXPANSION FOAM & TIES
MORTAR
RODS
SPACERS
SILICONE
 
Choose       Examples Gallery       Contact Us
    My Account      My Cart

First things first: calculate the wall opening

Before anything, you will need to calculate the wall opening for your Framelight Dry Fix kit. To calculate the wall opening area, take the following steps:

  1. Take the width of the block(190mm) and multiply by the number of glassblocks you need, we will use 6 for this example: 190mm x 6 = 1140mm
  2. Multiply the width of the spacer joint(14mm) by the number of inserts(5), and add 74mm and then add it to the above number: 14mm x 5 = 70mm + 74mm = 144mm
  3. The total: (190 x 6) + (14mm x 5 + 74mm) = 1284mm

Note: The Framelight Dry Fix Kit page will automatically calculate the correct opening size for you based on your selections.

Maximum Panel Size

2508mm high x 2508mm wide (98-3/4” x 98-3/4”) (12 x 12 blocks)

Step 1

Cut sections for the outer frame and assemble frame consisting of cill and two sides by using the clip and pin system (fig 1). Temporarily fix head piece leaving sides longer then necessary (position and fixing of clips for intermediate rows can be carried our later).

Step 2

Place blocks and vertical dividers to form first row (Fig 2).

Step 3

Insert pins in the centre of the ends of horizontal rails (fig 3). Lay rail in final horizontal position and locate clips and mark position of screws. Put rail to one side and screw fix the clips (fig 4). Clip rail into place (fig 5) (make sure the rail is seated down all the vertical dividers and blocks). Firmly secured

Step 4

Second and succeeding rows are placed by the same method positioning the clips as you go (Fig 6 & 7).

Step 5

Position and fix head piece into place and trim off any excess length of side sections.



These instructions are for guidance only. They are not intended to imply suitability for any purpose. Glass block panels are not load bearing. The Framelight Dry Fix System is not suitable for fire rated walls.

Related Links

  Framelight Dry Fix: An Introduction

  Buy a Framelight Dry Fix kit

Yes, we take phone orders! Call 01243 790 425 with your requirements and our staff will be happy to help.
 
About Us  |  Delivery & Shipping  |  Returns & Refunds  |  Tracking your order  |  Contact Us  |  Leave us Feedback  |  Site Map  |  Links